{"id":282,"date":"2024-02-02T10:22:00","date_gmt":"2024-02-02T09:22:00","guid":{"rendered":"https:\/\/gruposimec.biz\/blog\/?p=282"},"modified":"2024-01-10T03:23:24","modified_gmt":"2024-01-10T02:23:24","slug":"gas-refrigerante-co2-para-el-intercambio-de-calor-por-expansion-directa","status":"publish","type":"post","link":"https:\/\/gruposimec.biz\/blog\/gas-refrigerante-co2-para-el-intercambio-de-calor-por-expansion-directa\/","title":{"rendered":"Gas refrigerante CO2 para el intercambio de calor por expansi\u00f3n directa"},"content":{"rendered":"<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"331\" height=\"152\" src=\"https:\/\/gruposimec.biz\/blog\/wp-content\/uploads\/2024\/01\/descarga-23.jpg\" alt=\"\" class=\"wp-image-283\" srcset=\"https:\/\/gruposimec.biz\/blog\/wp-content\/uploads\/2024\/01\/descarga-23.jpg 331w, https:\/\/gruposimec.biz\/blog\/wp-content\/uploads\/2024\/01\/descarga-23-300x138.jpg 300w\" sizes=\"(max-width: 331px) 100vw, 331px\" \/><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\">ESPECIFICACIONES Y CARACTER\u00cdSTICAS DE LOS EVAPORADORES Y BATER\u00cdAS DE INTERCAMBIO DE CALOR PARA SU USO CON GAS REFRIGERANTE R744<\/h2>\n\n\n\n<p>El gas CO2 se considera un gas ecol\u00f3gico como refrigerante porque est\u00e1 presente en la atm\u00f3sfera, es accesible, y el proceso de preparaci\u00f3n como gas refrigerante no es contaminante y supone el reciclaje de uno de los gases con efecto invernadero m\u00e1s importante. Su impacto en la capa de ozono es nulo al ser usado como refrigerante y tiene un potencial de calentamiento (GWP) de valor 1. Adem\u00e1s no es inflamable ni t\u00f3xico.<\/p>\n\n\n\n<p>Sin embargo, su uso en sistemas de refrigeraci\u00f3n implica ciertas adaptaciones a los equipos debido a que el CO2 trabaja a presiones mucho m\u00e1s altas que los refrigerantes HFC o HFO habituales.&nbsp; El CO2 como gas condensa a temperaturas bajas, como m\u00e1ximo a 30\u00b0 porque su punto cr\u00edtico se encuentra sobre los 31 \u00baC. Como las presiones de condensaci\u00f3n son muy altas, hay que reforzar mec\u00e1nicamente las paredes de las tuber\u00edas para evitar roturas por fatiga o desgaste. Lo mismo sucede en el evaporador, ya que las presiones de evaporaci\u00f3n son tambi\u00e9n m\u00e1s elevadas y adem\u00e1s hay que prever qu\u00e9 suceder\u00e1 en caso de que paren m\u00e1quinas y suba la temperatura (subir\u00e1 tambi\u00e9n la presi\u00f3n).<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/www.sereva.es\/wp-content\/uploads\/2023\/09\/sereva-esquema-diametro-grosor-tubos.jpg\" alt=\"\" class=\"wp-image-13265\"\/><\/figure><\/div>\n\n\n<p>Por tanto, para condensar el gas CO2 en un sistema de refrigeraci\u00f3n que trabaje en zonas c\u00e1lidas, es necesario instalar complementos como eyectores o configurar una refrigeraci\u00f3n en cascada, en donde el evaporador realice la funci\u00f3n de condensador.<\/p>\n\n\n\n<p>El uso de un intercambiador de calor con gas CO2 como gas refrigerante queda regulado por la Directiva 2014\/68\/UE sobre Aparatos a Presi\u00f3n y el reglamento CE 1272\/2008).<\/p>\n\n\n\n<p>A partir de esta normativa que regula el dise\u00f1o de una tuber\u00eda que va a estar sometida a una presi\u00f3n, como es el caso de las tuber\u00edas de un evaporador, y de la f\u00f3rmula de tensi\u00f3n de rotura, obtenemos una tabla de espesores que debe tener el tubo del evaporador para asegurar las siguientes presiones:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Di\u00e1metro del tubo<\/th><th>Espesor del tubo<\/th><th>Presi\u00f3n m\u00e1xima<\/th><\/tr><\/thead><tbody><tr><td>9,52 mm<\/td><td>0,35 mm<\/td><td>44 bar<\/td><\/tr><tr><td>10 mm<\/td><td>0,35 mm<\/td><td>41 bar<\/td><\/tr><tr><td>12 mm<\/td><td>0,35 mm<\/td><td>34 bar<\/td><\/tr><tr><td>15,87 mm<\/td><td>0,38 mm<\/td><td>28 bar<\/td><\/tr><tr><td>19 mm<\/td><td>0,8 mm<\/td><td>51 bar<\/td><\/tr><tr><td>10 mm<\/td><td>0,6 mm<\/td><td>75 bar<\/td><\/tr><tr><td>9,52 mm<\/td><td>0,5 mm<\/td><td>65 bar<\/td><\/tr><tr><td>35 mm<\/td><td>1 mm<\/td><td>33 bar<\/td><\/tr><tr><td>42 mm<\/td><td>1 mm<\/td><td>28 bar<\/td><\/tr><tr><td>100 mm<\/td><td>4 mm<\/td><td>48 bar<\/td><\/tr><tr><td>9,52 mm<\/td><td>0,5 mm<\/td><td>65 bar<\/td><\/tr><tr><td>9,52 mm<\/td><td>0,6 mm<\/td><td>80 bar<\/td><\/tr><tr><td>9,52 mm<\/td><td>0,76 mm<\/td><td>105 bar<\/td><\/tr><tr><td>12 mm<\/td><td>0,6 mm<\/td><td>61 bar<\/td><\/tr><tr><td>12 mm<\/td><td>0,8 mm<\/td><td>85 bar<\/td><\/tr><tr><td>15,87 mm<\/td><td>0,76 mm<\/td><td>58 bar<\/td><\/tr><tr><td>15,87 mm<\/td><td>1 mm<\/td><td>80 bar<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">COEFICIENTE DE SEGURIDAD EN LA CERTIFICACI\u00d3N PARA CO2<\/h2>\n\n\n\n<p>El coeficiente de seguridad es una relaci\u00f3n entre la resistencia de un sistema y la carga o condici\u00f3n de dise\u00f1o que se le aplica. Un coeficiente de seguridad mayor a 1 indica que el sistema es capaz de soportar la carga o condici\u00f3n de dise\u00f1o sin problemas, mientras que un coeficiente de seguridad menor a 1 implica que el sistema no es lo suficientemente resistente y podr\u00eda fallar.<\/p>\n\n\n\n<p>En el caso de los evaporadores, en Sereva trabajamos con un coeficiente de seguridad del 4, lo que significa que la estructura es capaz de soportar una carga que es 4 veces mayor que la carga m\u00e1xima esperada en condiciones normales.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">CONCLUSIONES<\/h2>\n\n\n\n<p>A  partir de un coeficiente de seguridad 4, utilizamos estos di\u00e1metros de tubo para aplicaciones de los evaporadores con gas refrigerante R744 \u2013 CO2 y certificamos las siguientes presiones:<\/p>\n\n\n\n<p>Tubos de 3\/8 (di\u00e1metro interior de 9,52 mm), con espesor 0,6 mm y certificaci\u00f3n de hasta 80 bares.<\/p>\n\n\n\n<p>Tubo de 1\/2 (di\u00e1metro interior de 12 mm), con espesor de 0,8 mm y certificaci\u00f3n de hasta 80 bares.<\/p>\n\n\n\n<p>Tubo de 5\/8 (di\u00e1metro interior de 15,87 mm), con espesor de 1 mm y certificaci\u00f3n de hasta 80 bares.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>ESPECIFICACIONES Y CARACTER\u00cdSTICAS DE LOS EVAPORADORES Y BATER\u00cdAS DE INTERCAMBIO DE CALOR PARA SU USO CON GAS REFRIGERANTE<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"aioseo_notices":[],"featured_image_urls":{"full":"","thumbnail":"","medium":"","medium_large":"","large":"","1536x1536":"","2048x2048":"","morenews-featured":"","morenews-large":"","morenews-medium":""},"author_info":{"info":["GRUPO SIMEC"]},"category_info":"<a href=\"https:\/\/gruposimec.biz\/blog\/category\/sin-categoria\/\" rel=\"category tag\">Sin categor\u00eda<\/a>","tag_info":"Sin categor\u00eda","comment_count":"0","_links":{"self":[{"href":"https:\/\/gruposimec.biz\/blog\/wp-json\/wp\/v2\/posts\/282"}],"collection":[{"href":"https:\/\/gruposimec.biz\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gruposimec.biz\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gruposimec.biz\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/gruposimec.biz\/blog\/wp-json\/wp\/v2\/comments?post=282"}],"version-history":[{"count":1,"href":"https:\/\/gruposimec.biz\/blog\/wp-json\/wp\/v2\/posts\/282\/revisions"}],"predecessor-version":[{"id":284,"href":"https:\/\/gruposimec.biz\/blog\/wp-json\/wp\/v2\/posts\/282\/revisions\/284"}],"wp:attachment":[{"href":"https:\/\/gruposimec.biz\/blog\/wp-json\/wp\/v2\/media?parent=282"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gruposimec.biz\/blog\/wp-json\/wp\/v2\/categories?post=282"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gruposimec.biz\/blog\/wp-json\/wp\/v2\/tags?post=282"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}